Pod network duplication
Duplicate a configurable percentage of packets on a target Kubernetes pod's network namespace to test idempotency and dedup behavior.
Pod network duplication is a Kubernetes pod-level chaos fault that duplicates a configurable percentage of packets on the network path serving a target pod for a configurable duration. The receiver gets two copies of selected packets, which exercises TCP duplicate-segment handling and application-level dedup logic. Only the selected pods are affected; other pods on the node and the node's host networking are unaffected.
Use this fault to test how a service behaves when the network delivers duplicates: link flapping, mis-configured equal-cost multi-path (ECMP) routing, retransmit storms from an upstream proxy, or middleboxes that mirror traffic.
Use cases
Run this fault when you want to answer concrete questions like:
Idempotency of writes: Do duplicate requests on a non-idempotent API double-charge customers, double-publish events, or otherwise corrupt state?
UDP dedup: For DNS, QUIC, and custom UDP protocols, do clients dedup duplicate responses correctly, or do they get confused?
Mesh and proxy behavior: Do service mesh sidecars and load balancers drop the duplicates they receive, or do they forward them upstream?
Event-driven dedup: If your event bus uses at-least-once delivery, duplicates on the wire add to the workload. Does the consumer dedup using message IDs, or does it process the same event twice?
Prerequisites
Kubernetes version: 1.21 or later. Go to What's supported to confirm distribution support.
Target pods are Running: The application pods you intend to target are in the
Runningstate before the fault is launched.Privileged pods allowed: The cluster lets you schedule privileged pods in the chaos namespace.
Workload selector defined: The chaos experiment knows the target workload by kind, namespace, and either names or labels.
Supported environments
Amazon EKS
Supported
Azure AKS
Supported
Google GKE
Supported
Red Hat OpenShift
Supported
Rancher
Supported
VMware Tanzu
Supported
Self-managed Kubernetes (CNCF-certified)
Supported
GKE Autopilot
Supported with Autopilot setup
EKS Fargate, ACI virtual nodes
Not supported (no access to container runtime sockets)
Permissions required
The fault runs under the chaos infrastructure's service account.
Resource (apiGroup)
Verbs
Why it is needed
pods ("")
get, list, create, delete, deletecollection, patch, update
Discover target pods and run the chaos pod on the same node
pods/log ("")
get, list, watch
Stream chaos pod logs for status and debugging
deployments, statefulsets, replicasets, daemonsets (apps)
get, list
Resolve the target workload to the pods it owns
events ("")
get, list, create, patch, update
Record fault progress as Kubernetes events
jobs (batch)
get, list, create, delete, deletecollection
Run the chaos job that drives the fault
The default Harness chaos infrastructure service account already includes these permissions.
Fault tunables
Configure the following fault parameters when you add Pod network duplication to an experiment in Chaos Studio. Defaults are shown for reference.
Chaos parameters
NETWORK_PACKET_DUPLICATION_PERCENTAGE
Percentage of packets to duplicate on the matched flows. 100 duplicates every packet; 50 duplicates half.
100
CORRELATION
Duplication correlation as a percentage. 0 makes each packet independent; higher values clump duplicates.
""
TOTAL_CHAOS_DURATION
Duration of the fault in seconds.
60
Traffic filters
DESTINATION_IPS
Comma-separated list of destination IPs. Duplication applies only to packets headed to these IPs. Empty matches all destinations.
""
DESTINATION_HOSTS
Comma-separated list of destination hostnames. The helper resolves them and adds the resolved IPs to the filter.
""
SOURCE_PORTS
Comma-separated list of source ports on the target pod. Empty matches all source ports.
""
DESTINATION_PORTS
Comma-separated list of destination ports. Empty matches all destination ports.
""
NETWORK_INTERFACE
Network interface inside the target container's namespace. Almost always eth0 for standard CNI plugins.
eth0
Targeting
TARGET_PODS
Comma-separated list of pod names to target. Empty selects from the workload's pods using POD_AFFECTED_PERCENTAGE.
""
TARGET_CONTAINER
Container in the pod whose network namespace to enter. Empty targets the first container in the pod spec.
""
NODE_LABEL
Label selector to filter target pods by the node they run on. Empty disables node-based filtering.
""
POD_AFFECTED_PERCENTAGE
Percentage of the workload's pods to target. 0 means one pod.
0
SEQUENCE
When multiple pods are targeted, inject parallel (all at once) or serial (one after another).
parallel
Runtime and helper
CONTAINER_RUNTIME
Container runtime on the target nodes. One of containerd, docker, crio.
containerd
SOCKET_PATH
Path to the container runtime socket on the target node. Set to match CONTAINER_RUNTIME.
/run/containerd/containerd.sock
RAMP_TIME
Wait period in seconds before and after the fault. Go to ramp time to read how it is applied.
0
Tunables that apply to every chaos fault are documented in common tunables for all faults.
Configure for your container runtime
Set CONTAINER_RUNTIME and SOCKET_PATH to match the runtime on the target node:
CONTAINER_RUNTIME
SOCKET_PATH
containerd (default)
/run/containerd/containerd.sock
docker
/var/run/docker.sock
crio
/var/run/crio/crio.sock
Fault execution in brief
Configures the container's network interface to duplicate a specified percentage of packets (each duplicate carrying the same sequence number as the original), optionally scoping the effect to only certain destination IPs, hosts, or ports so other traffic passes through unaffected.
Expected behavior during fault execution
TCP receivers detect duplicate sequence numbers and discard the second copy; the connection continues normally. The cost is doubled traffic on the wire, which can saturate links.
UDP receivers (DNS, QUIC, custom protocols) see two packets. If the application is not idempotent, it processes the request twice.
TCP retransmit counters rise on the receiver side. CNI plugins that count packets may report inflated throughput.
For low duplication percentages (
10-25%), the impact is mainly bandwidth overhead. At high percentages (75+%), the receiver buffer can fill, and the connection slows or drops.Service mesh dedup at the proxy layer typically handles TCP duplicates well; UDP-based protocols are more exposed.
Signals to watch
Attach resilience probes to assert each layer:
Application-level dedup: Use an HTTP probe on an endpoint that tracks request idempotency, or a custom command probe.
Bandwidth usage: Use a Prometheus probe on your CNI's bytes-transferred metric.
Pod readiness: Use a Kubernetes probe to fail when the pod oscillates
NotReady.
Verify the fault execution effect
While the experiment is running, send traffic and confirm duplicates are reaching the receiver:
Send UDP traffic and count packets at the receiver.
Use
tcpdumpon the receiver to count incoming packets — you should see roughly(1 + NETWORK_PACKET_DUPLICATION_PERCENTAGE/100)× the sent count on matched flows.Observe TCP retransmit counters.
TCP receivers discard duplicate segments and counters reflect the activity.
Recovery and cleanup
End of duration: The duplication configuration is removed automatically and connectivity returns to normal within seconds.
Abort the experiment: Stopping the experiment from Chaos Studio triggers the same cleanup path.
Failed cleanup: If automated cleanup did not complete, restart the target pod to reset its network state.
Limitations
Serverless Kubernetes (EKS Fargate, ACI virtual nodes): These platforms do not allow the privileged access this fault needs. GKE Autopilot is supported once the one-time setup in Chaos on GKE Autopilot is in place.
Windows containers: This fault is supported on Linux pods only.
CNI plugins that bypass the pod's
eth0: Custom CNI plugins routing host-side may not be affected by this fault.hostNetworkpods: The fault refuses to inject onhostNetwork: truepods to avoid duplicating host traffic.Saturated links: Doubling traffic on a near-capacity link causes packet drops at the upstream switch or NIC. This can mask the duplication effect with apparent loss.
Troubleshooting
Related faults
Pod network loss: Drop packets instead of duplicating them.
Pod network latency: Add delay to packets.
Pod network corruption: Corrupt packets to test checksum handling.
Pod network rate limit: Throttle bandwidth on the path.
Common pod fault tunables: Shared environment variables for selecting target pods and workloads.
Last updated
Was this helpful?